- Degrees of freedom
- 20 active (4 per finger, every joint driven independently)
- End effector
- Five-finger hand; full thumb opposition and lateral abduction; minimum grasp diameter 0 mm
- Joint motor
- In-joint direct drive with FOC vector control; no tendons and no gear train, every axis back-drivable
- Manufacturer note
- Provisional: the manufacturer's documentation describes the 2.2 (Beta) build and states that values do not represent the final product. Fingertip force (12 N or more), open and close speed and joint backlash come from the manufacturer's web table for the earlier Beta. Payload, wrist load and moment, ingress protection, lifetime and repeatability are not published. The external interface (XT30 and RJ45) and the voltage range are reported to change in later 2.2 builds.
- Body dimensions
- Open hand, fingers together: about 180 x 80 x 40 mm (varies with pose). Finger length: index, middle and ring about 137 mm, little 134 mm, thumb 140 mm
- Structure and materials
- Three layers: skeleton (whole fingers replaceable with power off), a replaceable biomimetic soft layer and a passive skin that must always be worn
- Mounting
- Standard wrist flange, adapter and adapter flange in the box. One M3 and two M4 mounting holes under the palm; the palm-mount STEP file and A3 drawing are in the wuji-description repository. Left and right hands are mirror images with an identical mount interface
- In the box
- Hand, 12 V 20 A power adapter, AC cable, 2 m shielded Cat5e RJ45 cable, 2 m XT30 extension cable, adapter and adapter flange
- Software licence
- SDK, CLI, ROS 2 packages, models and retargeting under MIT; training repositories (wuji-mjlab, wuji-isaaclab) under Apache-2.0
- Availability
- The current build in the manufacturer's documentation is Wuji Hand 2.2 (Beta). The first-generation Wuji Hand was introduced in September 2025 with a USB interface; Hand 2 is the generation that followed